Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Catheter Cardiovasc Interv ; 103(3): 499-510, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38168895

RESUMEN

INTRODUCTION AND OBJECTIVES: Advanced chronic kidney disease (A-CKD) combined with atrial fibrillation increases the risk of both thrombogenic and bleeding events. Left atrial appendage occlusion (LAAO) may be an alternative to oral anticoagulation to prevent thromboembolic events. We aimed to evaluate the outcomes of LAAO in patients with A-CKD. METHODS: Comparison at long-term follow-up of patients diagnosed with and without A-CKD (eGFR<30 mL/min/1.73 m2 ) who underwent LAAO between 2009 and May 2022. RESULTS: Five hundred seventy-three patients were included. Eighty-one (14%) were diagnosed with A-CKD. There were no differences in sex, age, and cardiovascular risk factors, except for diabetes which was more frequent in patients with A-CKD. The control group had higher rates of stroke, both ischemic and hemorrhagic. There were no differences in the CHA2 DS2 -VASc score, although A-CKD patients had a higher bleeding risk according to the HASBLED scale. Global procedural success was 99.1%. At follow-up, there were no differences in stroke rate: at 1-year (HR: 1.22, IC-95%: 0.14-10.42, p = 0.861); at 5-years (HR: 0.60, IC-95%: 0.08-4.58, p = 0.594). Although bleeding events were higher in the A-CKD group, no differences were found in major bleeding (defined BARC ≥ 3) at 1-year (HR: 1.34, IC-95%: 0.63-2.88, p = 0.464) or at 5-years follow-up (HR: 1.30, IC-95%: 0.69-2.48, p = 0.434). Mortality rate at 5 years was higher in the A-CKD patients (HR: 1.84, IC-95%: 1.18-2.87, p = 0.012). CONCLUSIONS: LAAO is an effective and safe treatment in A-CKD patients to prevent ischemic events and bleeding. This strategy could be an alternative to oral anticoagulation in this high-risk group of patients.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Insuficiencia Renal Crónica , Accidente Cerebrovascular , Humanos , Estudios de Seguimiento , Apéndice Atrial/diagnóstico por imagen , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Hemorragia/prevención & control , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Anticoagulantes/efectos adversos
2.
J Clin Med ; 12(21)2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37959194

RESUMEN

BACKGROUND: Left atrial appendage occlusion (LAAO) is a safe and effective alternative to oral anticoagulation for thromboprophylaxis in patients with nonvalvular atrial fibrillation. Technological development in devices and imaging techniques, as well as accumulated experience, have increased procedural success rates and decreased complications. Same-day discharge protocols have been proposed in the field of structural heart disease, but this approach has not been studied in detail for the LAAO procedure. AIM: The aim of this study is to assess the safety and efficacy of an outpatient program for LAAO when compared to the conventional treatment approach. METHODS: We present a retrospective, non-randomized single-center study of 262 consecutive patients undergoing LAAO. Patients were divided into two groups, the first (n = 131) followed a conventional protocol (CP), and the second (n = 131) an outpatient protocol (OP). The primary composite endpoint comprised MACCE (death, stroke, and bleeding), cardiac tamponade, vascular complication, or attendance in the emergency department after hospital discharge at 30 days. RESULTS: The overall success rate was 99.6%, with a periprocedural complication rate of 2.29%. With regards to the CP versus OP group, there were no differences between incidences of the primary composite endpoint (6.1% PC vs. 3.0% PA, p = 0.24), or after an analysis, with propensity score matching. No differences were observed in the individual endpoints. There was a decrease in hospital length of stay in the same-day discharge group (p < 0.01). CONCLUSIONS: A same-day discharge LAAO program is safe, effective, and feasible when compared to the conventional strategy. Moreover, it reduces hospital length of stay, which might have clinical and economic benefits.

3.
J Clin Med ; 11(16)2022 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-36013075

RESUMEN

BACKGROUND: Paravalvular leak occurs in 5-17% of patients following surgical valve replacement, more often in mitral position. The prognosis without treatment is poor. Percutaneous device closure represents an alternative to repeat surgery. The objective of this work is to evaluate the medium and long-term results in the percutaneous closure of PVL in mitral prosthesis. METHODS: This observational study is based on a retrospective registry including consecutive mitral PVL cases undergoing percutaneous closure at a single tertiary-care center from April 2010 to December 2020. The safety and efficacy results of the procedure, at 90 days and in the long term, were analyzed. Also, predictors of procedure failure and long-term events were identified. RESULTS: A total of 128 consecutive mitral paravalvular leak closure procedures were included. Technical success was achieved in 115 (89.8%) procedures. The presence of multiple PVLs was the sole factor that independently predicted procedural failure. Median follow-up of our sample was 41.8 months (mean 47.7 ± 35.7 months). Underlying hemolytic anemia as the indication for PVL closure, a recent admission for decompensated HF, and lack of improvement in functional class emerged as consistent predictors of MACE and death during long-term follow-up, while lack of procedural success during the first PVL procedure and chronic kidney disease were also associated with MACE during follow-up. CONCLUSIONS: Percutaneous mitral PVL closure displayed high technical and procedural success rates, with an acceptable safety profile, in a high-risk population. Percutaneous mitral PVL closure achieved an improvement in short- and long-term functional class and a reduction of hemolysis in the vast majority of patients. In addition, long-term survival in our study was good, in particular for patients undergoing successful PVL closure procedures.

7.
Rev. chil. cardiol ; 39(2): 154-158, ago. 2020. graf
Artículo en Español | LILACS | ID: biblio-1138528

RESUMEN

Abstract Atrial fibrillation (AF) is an increasing health care problem associated with thromboembolic risk about 5% per year, with high mortality and morbidity when associated to stroke. Oral anticoagulants (OAC) are the treatment of choice for preventing ischemic stroke in patients with nonvalvular atrial fibrillation (NVAF). However, these drugs are associated with an increased risk of serious complications such an intracranial hemorrhage (ICH). In this context percutaneous closure of the left atrial appendage (LAA) is an effective therapeutic alternative to OACs, with an increasing success rate. Novel devices might allow or facilitate the procedure in some anatomically and technically complicated cases. Two patients with a complex morphology of the LAA, in which the LAmbre (Lifetech Scientific [Shenzhen] Co. Ltd.) device was implanted with good technical and clinical results are presented.


Asunto(s)
Humanos , Femenino , Anciano de 80 o más Años , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Apéndice Atrial/diagnóstico por imagen , Dispositivo Oclusor Septal , Fibrilación Atrial/diagnóstico por imagen , Angiografía , Ecocardiografía , Cateterismo Cardíaco/métodos , Accidente Cerebrovascular/prevención & control
14.
Rev Port Cardiol ; 36(3): 219.e1-219.e4, 2017 Mar.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-28245948

RESUMEN

We present the case of a patient with a high-output fistula between the right superficial femoral artery and femoral vein after left atrial appendage closure successfully treated with a PK-Papyrus covered coronary stent using a 6F guiding catheter. To the best of our knowledge this is the first time a PK-Papyrus coronary stent has been used in this setting.


Asunto(s)
Fístula Arteriovenosa/cirugía , Arteria Femoral/cirugía , Vena Femoral/cirugía , Complicaciones Posoperatorias/cirugía , Stents , Anciano de 80 o más Años , Fístula Arteriovenosa/etiología , Femenino , Humanos , Enfermedad Iatrogénica , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Vasculares/métodos
20.
J Interv Cardiol ; 29(4): 382-92, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27242018

RESUMEN

Paravalvular leak (PVL) is an uncommon yet serious complication associated with the implantation of mechanical or bioprosthetic surgical valves and more recently recognized with transcatheter aortic valves implantation (TAVI). A significant number of patients will present with symptoms of congestive heart failure or haemolytic anaemia due to PVL and need further surgical or percutaneous treatment. Until recently, surgery has been the only available therapy for the treatment of clinically significant PVLs despite the significant morbidity and mortality associated with re-operation. Percutaneous treatment of PVLs has emerged as a safe and less invasive alternative, with low complication rates and high technical and clinical success rates. However, it is a complex procedure, which needs to be performed by an experienced team of interventional cardiologists and echocardiographers. This review discusses the current understanding of PVLs, including the utility of imaging techniques in PVL diagnosis and treatment, and the principles, outcomes and complications of transcatheter therapy of PVLs.


Asunto(s)
Fuga Anastomótica/cirugía , Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Reoperación/métodos , Técnicas de Cierre de Heridas , Fuga Anastomótica/diagnóstico , Fuga Anastomótica/etiología , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...